GFZ Aluminum-Alloy Jaw Couplings with Locking Assemblies
GFZ couplings use aluminum-alloy jaw hubs, a flexible spider and end-face locking assemblies. Multiple axial locking screws secure the hub to the shaft. This is not the side-screw clamp construction used by GFC couplings. Select the outside-diameter/length model, then confirm the finished bores d1 and d2 for the two shafts.
Models and Dimensions
| Model and offered bore range | Outside diameter | Length | LF / LP | Locking screw | Source tightening torque (N m) |
|---|
| GFZ-55x78 / Bore 12-32 mm | 55 mm / 2.165 in | 78 mm / 3.071 in | 46.2 / 16.5 mm | M5 | 4 |
| GFZ-65x90 / Bore 17-38 mm | 65 mm / 2.559 in | 90 mm / 3.543 in | 52.9 / 18 mm | M5 | 4 |
| GFZ-80x114 / Bore 19-45 mm | 80 mm / 3.150 in | 114 mm / 4.488 in | 67 / 22.5 mm | M6 | 7 |
Ordering and Machining
One selected option is one coupling assembly. The bore range is configurable and is not a statement that every intermediate bore is stocked. Specify both finished bore diameters, shaft tolerances, shaft engagement and any required keyway before manufacture. The supplier gives H7 as a standard bore reference; confirm the finished machining requirements for the order. No fixed bore pair, additional machining service or fixed lead time is implied.
Construction
The original engineering and exploded views show the jaw hubs, flexible spider, end-face locking rings and axial screws. The source identifies aluminum alloy for the listed GFZ series. It does not establish an exact alloy grade, ring material, spider formulation or hardness for these options. Steel GFZS configurations are not included on this page. Confirm component materials when required for the application.
Technical Selection
The supplier table below retains model-specific torque, speed, permissible radial/angular/axial offsets, static torsional stiffness and mass. These values are catalogue references, not independent test or certification results. Shaft holding and finished bore configuration affect the torque transmitted. Locking-screw tightening torque is not the coupling torque rating. The source inertia column has an inconsistent unit label; its values are shown with the unit marked unconfirmed and must not be used as a verified inertia specification.
Product Photographs and Drawings
The original photograph is engraved GFZ-55X78 and is assigned only to the 55x78 option. Other model images use the original GFZ engineering view with their own catalogue dimensions, not a resized photograph of another size. Inch conversions are approximate and use three decimal places. The exploded view explains component arrangement, not extra separately supplied parts. The supplied drawings are catalogue references, not production approval drawings.
Installation
Confirm both shafts, fit, insertion depth and access to the end-face locking screws before ordering. Align the shafts and use the confirmed model-specific tightening procedure. Check the intended torque, speed and permissible alignment offsets for the application. Isolate the equipment before installation or maintenance and use suitable guarding.