Double-acting HFR angular pneumatic grippers in through-hole mounting and supplier-designated high-temperature versions. The source identifies the HFR family as a 180-degree opening type.

Construction and configuration

Manufacturing originMainland China
Body materialAluminium alloy
OperationDouble acting, angular opening
Opening type180-degree HFR series
Mounting variantsN: through-hole mounting
Temperature variantsSupplier-designated high-temperature options; final seal/rating must be confirmed

Model selection and supplied components

  • The _N configurations identify through-hole mounting in this source.
  • High-temperature versions retain their original HFR model designation; the configuration label distinguishes them from the standard version.
  • Confirm the required operating temperature, seal specification and installation conditions before ordering a high-temperature version. No temperature limit is inferred from its name.

Installation and sensing

Use the mounting faces and hole pattern shown in the matched drawing. Keep sufficient clearance throughout the opening and closing movement. The port thread, mounting thread and threaded-hole depth are different specifications; use the callout for the relevant feature. Connect the pneumatic supply to the illustrated ports. Select the sensor model and wiring for the machine; a built-in magnet does not by itself mean that an external sensor is supplied.

How to read the dimensions

Original dimension leaders and source numerical values are retained in the model drawings below. O means open, C means closed, THRU means through hole, and d means depth. M designations identify metric threads. Millimetre values and approximate inch conversions are listed in the model-specific table. Each drawing is identified by its complete model and configuration; similar-looking models may have different jaw geometry, mounting holes or overall length.

Product construction and mounting features
Product construction and mounting features

HFR 180 Degree Grippers, Through-Hole and High-Temperature Versions

Double-acting HFR angular pneumatic grippers in through-hole mounting and supplier-designated high-temperature versions. The source identifies the HFR family as a 180-degree opening type.

Quick selection

  • The _N configurations identify through-hole mounting in this source.
  • High-temperature versions retain their original HFR model designation; the configuration label distinguishes them from the standard version.
  • Confirm the required operating temperature, seal specification and installation conditions before ordering a high-temperature version. No temperature limit is inferred from its name.

Construction and installation

The original product views show the body, jaws, mounting interfaces and pneumatic connections. Check the exact model drawing for bore, jaw travel, port thread, hole spacing, thread depth and clearance throughout the movement. Series-reference tables may include configurations outside the selectable options below.

Magnetic sensing provisions and illustrated sensor types are configuration references. Confirm the required sensor, wiring, fittings and included parts before ordering.

Dimensions and operating reference

Dimensional drawings retain the supplied millimetre values. Convert with 1 in = 25.4 mm. Nominal dimensions, grip-force references and operating limits depend on the selected configuration. Confirm critical dimensions, pressure, temperature and gripping-point conditions before installation.

Drawing abbreviations: O/C = open/closed; DA/SA = double/single acting; NO/NC = normally open/closed; THRU = through hole; Thd = thread; d = depth; L = length; EXT/INT = external/internal grip; cyc/min = cycles per minute. Grip-force tables are references at the stated pressure and gripping point.

Available configurations

Model / configurationSKU
HFR10_N | THRU mount5778514978715
HFR16_N | THRU mount5778514978716
HFR20_N | THRU mount5778514978717
HFR25_N | THRU mount5778514978718
HFR32_N | THRU mount5778514978719
HFR10 | High-temp version5836528383690
HFR16 | High-temp version5836528383691
HFR20 | High-temp version5836528383692
HFR25 | High-temp version5836528383693
HFR32 | High-temp version5836528383694

Product and technical references

HFR 180 Degree Grippers, Through-Hole and High-Temperature Versions original product view 1

HFR 180 Degree Grippers, Through-Hole and High-Temperature Versions original product view 2

HFR 180 Degree Grippers, Through-Hole and High-Temperature Versions original product view 3

Model dimensions: millimetres and inches

Choose the exact model and mounting form. Inch values are approximate conversions of the supplied metric dimensions. Thread designations remain metric or PT as specified.

Model / configurationMeasurementMetric / original valueInches (approx.)
HFR10_N | THRU mountCylinder bore10 mm0.3937
HFR10_N | THRU mountAir-port threadM5 x 0.8—
HFR10_N | THRU mountTapped-hole callout 12 x M3 x 0.5; depth 4 mm0.1575
HFR16_N | THRU mountCylinder bore16 mm0.6299
HFR16_N | THRU mountAir-port threadM5 x 0.8—
HFR16_N | THRU mountTapped-hole callout 12 x M4 x 0.7; depth 5 mm0.1969
HFR20_N | THRU mountCylinder bore20 mm0.7874
HFR20_N | THRU mountAir-port threadM5 x 0.8—
HFR25_N | THRU mountCylinder bore25 mm0.9843
HFR25_N | THRU mountAir-port threadM5 x 0.8—
HFR25_N | THRU mountTapped-hole callout 12 x M6 x 1.0; depth 10 mm0.3937
HFR32_N | THRU mountCylinder bore32 mm1.2598
HFR32_N | THRU mountAir-port threadM5 x 0.8—
HFR10 | High-temp versionCylinder bore10 mm0.3937
HFR10 | High-temp versionAir-port threadM5 x 0.8—
HFR10 | High-temp versionTapped-hole callout 12 x M3 x 0.5; depth 4 mm0.1575
HFR16 | High-temp versionCylinder bore16 mm0.6299
HFR16 | High-temp versionAir-port threadM5 x 0.8—
HFR20 | High-temp versionCylinder bore20 mm0.7874
HFR20 | High-temp versionAir-port threadM5 x 0.8—
HFR25 | High-temp versionCylinder bore25 mm0.9843
HFR25 | High-temp versionAir-port threadM5 x 0.8—
HFR32 | High-temp versionCylinder bore32 mm1.2598
HFR32 | High-temp versionAir-port threadM5 x 0.8—

Original model dimension drawings

Expand the exact model below to view its supplied dimension drawing. Click the image to open the original uploaded resolution. Dimensions remain in millimetres; approximate inch conversions are in the model table above.

HFR10_N | THRU mount
HFR10_N | THRU mount dimensional reference
HFR10_N | THRU mount dimensional reference
HFR16_N | THRU mount
HFR16_N | THRU mount dimensional reference
HFR16_N | THRU mount dimensional reference
HFR20_N | THRU mount
HFR20_N | THRU mount dimensional reference
HFR20_N | THRU mount dimensional reference
HFR25_N | THRU mount
HFR25_N | THRU mount dimensional reference
HFR25_N | THRU mount dimensional reference
HFR32_N | THRU mount
HFR32_N | THRU mount dimensional reference
HFR32_N | THRU mount dimensional reference
HFR10 | High-temp version
HFR10 | High-temp version dimensional reference
HFR10 | High-temp version dimensional reference
HFR16 | High-temp version
HFR16 | High-temp version dimensional reference
HFR16 | High-temp version dimensional reference
HFR20 | High-temp version
HFR20 | High-temp version dimensional reference
HFR20 | High-temp version dimensional reference
HFR25 | High-temp version
HFR25 | High-temp version dimensional reference
HFR25 | High-temp version dimensional reference
HFR32 | High-temp version
HFR32 | High-temp version dimensional reference
HFR32 | High-temp version dimensional reference

Model / configuration / SKU

HFR 180 Degree Grippers, Through-Hole and High-Temperature Versions
Model / configurationSKU
HFR10_N | THRU mount 5778514978715
HFR16_N | THRU mount 5778514978716
HFR20_N | THRU mount 5778514978717
HFR25_N | THRU mount 5778514978718
HFR32_N | THRU mount 5778514978719
HFR10 | High-temp version 5836528383690
HFR16 | High-temp version 5836528383691
HFR20 | High-temp version 5836528383692
HFR25 | High-temp version 5836528383693
HFR32 | High-temp version 5836528383694