JXK-14 AC Pulse Current Sensor Open Loop Current Transmitter Hall Current Sensor AC Current Transducer
Notes: If you want to have the customization,please contact us.
Introduction
<1>. Working principle: open loop direct measurement.
<2>. Usage: Used for measuring DC, AC, pulse current and other arbitrary waveform current.
<3>. Advantages: Better cost performance, low power consumption, small volume, light weight, easy installation, perforation input and no insertion loss.
<4>. Application: Frequency conversion speed control system, electric welding machine, electrochemistry, power supply monitoring, electric locomotive, low level starting protection.
<5>. The input, output, power and outer shell are isolated, with strong anti-interference ability and high reliability.
<6>. Full channel configuration,Parameter customizable.
Technical parameters
|
Power Supply
|
|
Power supply
|
DC5V, DC12V, DC15V, DC24V, ±15V, DC12~28V,
AC220V, Customizable
|
|
Input
|
|
Input signal
|
AC/ DC 0~150A
|
|
Output
|
|
Output signal
|
4-20mA, 0-20mA, 0-5V, 0-10V, Customizable
|
|
Other Parameters
|
|
Installation
|
Standard rail +Plane screw fixation
|
|
Aperture available
|
4mm, 8mm, 12mm
|
|
Accuracy
|
0.5%F.S.
|
|
Respond time
|
<200ms
|
|
Linearity
|
0.5%F.S.
|
|
Temperature drift
|
≤500PPM/℃
|
|
Band width
|
DC~20KHz
|
|
Consumption of current
|
≤25mA
|
|
Isolation voltage resistance
|
2.5k/50Hz,1Min
|
|
Offset voltage
|
≤20mvV
|
|
Zero output
|
≤0.15mA
|
|
Di/dt follow
|
>50A/uS
|
|
Working ambient
|
-10℃~+70℃
|
|
Storage ambient
|
-25℃~+85℃
|